ATP Bioluminescence Assay Kit HS II

ROCHE/11699709001 - sufficient for 500 assays (tubes), sufficient for 1,000 assays (microplate), kit of 1 (4 components), suitable for detection

Synonym: Bioluminescence assay

Product Type: Chemical

Catalog Number PKG Qty. Price Quantity
45-11699709001 1000 assays
$0.00
1/EA
CALL FOR PRICE
Add To Favorites

 

application(s) detection
assay >98%
manufacturer/tradename Roche
packaging kit of 1 (4 components)
Quality Level 100 
shipped in dry ice
storage temp. −20°C
usage sufficient for 1,000 assays (microplate)
  sufficient for 500 assays (tubes)
Application: Highly sensitive and quantitative determination of ATP. Contains a cell lysis reagent and can be applied for the detection of microbial contamination. The kit is well suited for use in tube luminometers and microplate-format luminometers. The cell lysis reagent exhibits good lysis efficiency with respect to a variety of eukaryotic and prokaryotic cells.
For a time constant light signal, use the ATP Bioluminescence Assay Kit CLS II.
For maximum sensitivity, the sample ATP must be in a minimum volume, and the luciferase reagent must not be diluted.
Biochem/physiol Actions: The luciferase from Photinus pyralis (American firefly) catalyzes the following reaction:
ATP + D-luciferin + O2? oxyluciferin + PPi + AMP + CO2 + light.
The quantum yield for this reaction is about 90%. The resulting green light has an emission maximum at 562 nm.
The Michaelis equation has the following form:
light intensity = (Vmax x CATP)/(Km + CATP).
At low ATP concentrations (CATPm), the formula is simplified to light intensity = Vmax x CATP/Km.
From this equation, it becomes obvious that the light output is directly proportional to the ATP concentration (CATP), and is dependent on the amount of luciferase (Vmax) present in the assay.
General description: Living things require a continual input of free energy for three major purposes: the performance of mechanical work in muscle contraction and other cellular movements, the active transport of molecules and ions, and the synthesis of macromolecules and other biomolecules from simple precursors.
The free energy used in these processes is derived from the surroundings and maintains an organism in a state that is far from equilibrium. In most processes, this special carrier of free energy is adenosine triphosphate (ATP), an energy-rich molecule. Its triphosphate unit contains two phosphoanhydride bonds. The turnover of ATP is very high. Motion, active transport, signal amplification, and biosynthesis (as is needed for cell proliferation) can occur only if ATP is continuously regenerated from ADP. Therefore, measurement of ATP can serve as a marker for cell proliferation.
The determination of ATP using bioluminescence is a well established technique. It uses the ATP dependency of the light-emitting, luciferase-catalyzed oxidation of luciferin for the measurement of extremely low concentrations of ATP.
Other Notes: For life science research only. Not for use in diagnostic procedures.
Packaging: 1 kit containing 4 components.
Preparation Note: Working concentration: 10-5 to 10-12 M ATP
Working solution: Preparation of Working Solutions

Luciferase Reagent
Dissolve the whole content of one vial 1 by carefully adding 10 ml of dilution buffer from vial 4. Incubate for 5 minutes at 0 to 4 °C without stirring or shaking. Mix for a homogeneous solution by carefully rotating the bottle. Do not shake!
Stability: Set up a standard curve each day, because a slight loss of luciferase activity may occur during this time (approx. 20% after storage for 5 days at 2 to 8 °C).

ATP Standard
Information Note:
Each bottle contains approx. 10 mg ATP (> 98% purity; Mr 605.2). The exact amount of ATP is determined individually for each lot as indicated on the label.
Dissolve the content of one vial 2 by addition of the appropriate volume of dilution buffer to get a final concentration of 10 mg/ml or 16.5 mM, respectively (e.g., 960 μl to 9.60 mg ATP).
The ATP standard curve is prepared by serial dilutions of one ATP standard with dilution buffer.

Cell Lysis Reagent
The cell lysis reagent is ready-to-use.
Important Note: Avoid contamination by microorganisms or ATP. The use of autoclaved or heat sterilized labware is recommended.

Dilution Buffer
The dilution buffer supplied with the kit is essentially free of ATP and microbial contaminations. Use this buffer for reconstitution and dilution of the kit reagents. It can also be used as diluent for samples.
Important Note: Avoid contamination and use autoclaved or heat sterilized labware.
Storage conditions (working solution): Luciferase Reagent
The reagent is stable for one day at 15 to 25 °C or for one week when stored at 0 to 4 °C.
Reconstituted Luciferase Reagent may be stored frozen at -15 to -25 °C for longer periods of time.
Important Note: Each freeze/thaw-cycle reduces luciferase activity, depending on the freezing conditions (shock freezing is most effective). For best results, avoid repeated freezing and thawing.
ATP Standard
When stored at 2 to 8 °C, the solution is stable for one week (< 5% degradation).
When stored at 15 to 25 °C, the solution is stable for at least 4 weeks (< 5% degradation).
When stored on ice, diluted ATP-standards are stable for 8 hours.
Cell Lysis Reagent
The reagent is stable at 2 to 8 °C.
Dilution Buffer
Store at 2 to 8 °C.
Specificity: The ATP Bioluminescence Assay Kit HS II is specifically developed for the high-sensitivity detection of ATP. Due to the high concentration of luciferase in the assay, the reaction exhibits a peak kinetic. If ATP determinations are performed to obtain kinetic data of the enzymes involved (e.g., for metabolic studies or if coupled enzymatic assays are applied), the use of the ATP Bioluminescence Assay Kit CLS II (generating a constant light signal) is highly recommended.
RIDADR NONH for all modes of transport
WGK Germany WGK 3
Flash Point(F) does not flash
Flash Point(C) does not flash
Purity >98%
Storage Temp. −20°C
UNSPSC 12352204
Components Luciferase Reagent, lyophilized (5); ATP Standard, lyophilized (5); Cell Lysis Reagent ready-to-use; Dilution Buffer ready-to-use

The following items have been added to your cart:

Choose a favorite list for this item:

Catalog Number Description Price
$

Returns/Order support

Please fill out the form below if you want to request order support from Krackeler Scientific.


Quick Order

* Required


New Year Price Updates

We are currently working diligently to update our website pricing information for the New Year. If you place an order, you will be acknowledged with any corrected pricing. If you'd like the most current information sooner, please don't hesitate to drop us an email or give us a call and we'd be happy to assist. Thank you for your patience while we are updating.

800-334-7725
office@krackeler.com


Play Video

To Request a Quote

  1. Search or Browse for items and add to them to your Shopping Cart.
  2. Click the "Request Quote" button at the bottom of the Shopping Cart page.
  3. Fill out required fields.
  4. Optionally you can convert to standard checkout mode by choosing a payment type.
  5. Click "Request Quote" at the bottom of the page.

You will be contacted with a quote.

To Order From a Quote

  1. Register and login to the website.
  2. Receive a quote from your sales representative or customer service.
  3. Have your copy of the quote in hand.
  4. Visit our quote module to search for your quote.
Back to Top