SLB®-ILPAH Capillary GC Column
SUPELCO/29799-U - L × I.D. 20 m × 0.18 mm, df 0.05 μm
Product Type: Equipment/Book
| application(s) | food and beverages |
| Beta value | 900 |
| column type | capillary polar |
| df | 0.05 μm |
| L × I.D. | 20 m × 0.18 mm |
| material | fused silica |
| matrix active group | Non-bonded; 1,12-di(tripropylphosphon |
| parameter | ≤25-300 °C temperature (isothermal or programmed) |
| Quality Level | 100 ![]() |
| technique(s) | gas chromatography (GC): suitable |
| Application: | Retention behavior of alkyl-substituted polycyclic aromatic sulfur heterocycle isomers in gas chromatography on stationary phases of different selectivity This study investigates the retention behavior of polycyclic aromatic sulfur heterocycles (PASHs) using gas chromatography with different stationary phases, including ionic liquids (ILs). The IL phase demonstrated unique selectivity and correlation with PASH geometry. (Wilson, Lee, et al, 2017) https://doi.org/10.1016/j ![]() Retention behavior of isomeric polycyclic aromatic sulfur heterocycles in gas chromatography on stationary phases of different selectivity The research evaluates the gas chromatographic retention indices of alkyl-substituted PASHs using various stationary phases, including ionic liquids. Results indicate that ILs offer distinct selectivity and thermal stability, enhancing the separation of complex mixtures. (Wilson, Lee, et al, 2017) https://doi.org/10.1016/j ![]() Ultra-high thermal stability perarylated ionic liquids as gas chromatographic stationary phases for the selective separation of polyaromatic hydrocarbons and polychlorinated biphenyls This article explores the use of perarylated ionic liquids as stationary phases in gas chromatography for separating polycyclic aromatic hydrocarbons and polychlorinated biphenyls. The ILs exhibit high thermal stability and unique selectivity, improving the resolution of challenging analytes. (Anderson & Davis, 2019) https://doi.org/10.1016/j ![]() |
| General description: | Application: This special purpose and specially tested capillary GC column is designed for the analysis of polycyclic aromatic hydrocarbons (PAHs). It incorporates an ionic liquid stationary phase. Each column is individually tested to ensure resolution of several key sets (phenanthrene/anthracene, benzo[a]anthracene/chryse USP Code: None Phase: Non-bonded; 1,12-Di(tripropylphosphon Temp. Limits: Subambient to 300 °C (isothermal or programmed) |
| Legal Information: | SLB is a registered trademark of Merck KGaA, Darmstadt, Germany |
| WGK Germany | WGK 3 |
| Flash Point(F) | Not applicable |
| Flash Point(C) | Not applicable |
| UNSPSC | 41115710 |

